Gold vs. platinum-iridium tip catheter for cavotricuspid isthmus ablation: the AURUM 8 study

2010

Aims Gold electrodes have the theoretical advantage of creating bigger lesions than platinum–iridium (Pt–Ir) electrodes. We performed a prospective randomized study to compare the clinical efficacy of standard 8 mm Pt–Ir tip catheter (control) and 8 mm gold-tip catheters in the ablation of the cavotricuspid isthmus (CTI)-dependent atrial flutter. Methods and results A total of 463 patients undergoing CTI ablation in 19 clinical centres were randomized to receive the treatment by gold-tip or control catheter. The primary endpoint was cumulative radiofrequency (RF) application duration until achieving bidirectional CTI block. It did not differ significantly for the two catheters. The gold-tip…

MaleCavotricuspid isthmusmedicine.medical_specialtymedicine.medical_treatmentCatheter ablation030204 cardiovascular system & hematologyIridium03 medical and health sciences0302 clinical medicineRecurrencePhysiology (medical)medicineHumansFluoroscopyProspective Studies030212 general & internal medicineClinical efficacyElectrodesAgedPlatinumRetrospective Studiesmedicine.diagnostic_testbusiness.industryThermal ConductivityMiddle AgedAblationmedicine.disease3. Good healthSurgeryCatheterTreatment OutcomeAtrial FlutterCatheter AblationFemaleGoldCardiology and Cardiovascular MedicinebusinessAtrial flutterFollow-Up StudiesTip catheterEuropace
researchProduct

Study of three urethral pressure recording devices: Theoretical considerations

1978

Using a bladder-urethra model, 2 perfusion catheters (open side and open tip) were compared to the balloon catheter. The most accurate results were obtained using the balloon catheter. Based on the law of continuity and Bernouilli's law, the disadvantage of the open side catheter is due to the inconstant diameter of the sum of the side holes. Therefore, the measured pressure is not necessarily identical to the real pressure. The open tip catheter measures the opening pressure and the recorded pressure does not necessarily reflect the pressure at the site of the tip hole. The balloon catheter has elastic and plastic characteristics. Optimum results were obtained only with prestretch of the b…

Malemedicine.medical_specialtyManometrybusiness.industryUrologyUrinary BladderBalloon catheterBalloonBiomechanical PhenomenaSurgeryModels StructuralCatheterUrethraUrethral pressureHydrostatic PressurePressuremedicineHumansUrinary CatheterizationbusinessTip catheterBiomedical engineeringUrological Research